Repair
Siemens SINAMICS

SINAMICS G120 · G120C · G120D · G150 · G180 · S120 · S150 · S110

Specialist service of Siemens SINAMICS inverters — replacement of IGBT and DC-link capacitors, repair of CU240/CU250/CU320 control cards, Power Module PM service, parameterization via STARTER and TIA Portal. No-obligation quote, 12-month warranty.

✅ Diagnostics included in repair ⚡ Priority quote 🛡️ 12-month warranty 🚚 Courier pickup from all of Europe 💾 Parameter backup STARTER/TIA

Service SINAMICS: G120, G150, S120 and other models

⚡

SINAMICS G120 / G120C

Repair of G120 inverters with Power Module PM240/PM250/PM260 and Control Unit CU240B-2/CU240E-2/CU250S-2. Replacement of IGBT, capacitors, service of PROFIBUS/PROFINET ports.

⚙️

SINAMICS G150 / G180

Repair of cabinet G150 and G180 inverters (up to 2800kW). Service of IGBT power section, pre-charge circuits, CU320-2 regulator cards and supply transformer.

🔋

SINAMICS S120 (serwo)

Repair of S120 servo drive modules: Control Unit CU320, Active Line Module (ALM), Single/Double Motor Module. Service of DRIVE-CLiQ and axis cards.

🖥️

CU240 / CU250 / CU320 cards

Repair of Control Unit cards: CPU, internal power supply, Profibus/Profinet interfaces, digital and analog I/O, DRIVE-CLiQ channel.

🌡️

SINAMICS S150 (4Q)

Repair of 4-quadrant S150 inverters (regenerative). Service of Active Infeed Module, regulator cards and braking circuits.

💾

Parameterization and commissioning

Backup of .zip/.dxp (STARTER) or TIA Drive file before repair. After repair, full parameterization and load test. We provide a test results sheet.

Why EFIXLAB?

Siemens SINAMICS authorized know-how

  • STARTER / TIA Portal Drive backup — project backup before repair, restoration after. Parameters are returned identical to the originals.
  • Old SIMOVERT / MM4 series (EOL) — we repair discontinued Micromaster 420/430/440 and SIMOVERT Masterdrives. We have parts for these discontinued models.
  • Full S120 chain — ALM, SM, SLM, CU320, DRIVE-CLiQ cables all in one service location.
  • Load test — every inverter after repair is tested under motor load, not just at no-load.
  • Priority for stopped production — we respond to priority requests first.
  • 12-month warranty — on all performed work.

How does repair work for SINAMICS?

1

Request
online or by phone

2

Shipping
by courier

3

Param backup
+ diagnostics

4

Quote
no obligation

5

Repair
& testing

6

Return
with warranty

Report fault SINAMICS — no-obligation quote

Provide the SINAMICS model, power rating and alarm description (F/A code). Our Siemens specialist will get back to you with a diagnosis.

Przeciągnij pliki lub kliknij, aby wybrać
Maks. 10 plików · do 20 MB każdy · PDF, JPG, PNG, TXT, ZIP

Priority response. Diagnostics included in repair.

Dziękujemy! We have received your request — our SINAMICS specialist will contact you shortly.

Frequently asked questions

Yes — we repair discontinued Micromaster MM420, MM430 and MM440 and SIMOVERT Masterdrives. These models represent a large share of requests from production plants.

Yes — if the CU card is operational, backup can be done via STARTER or TIA Portal Drive. After repair, parameters are restored identically.

Yes — we repair S120 in Booksize and Chassis configuration, including ALM, single and dual-axis SM, SLM and CU320-2. Service includes DRIVE-CLiQ and encoder cards.

Diagnostics: 1–2 business days. Repair after approval: 5–7 business days (after receiving necessary components). Express mode for stopped production. As a rule — repair time may be significantly extended depending on component availability and repair complexity. Deadlines are agreed individually with the client.

Siemens Drive Repair — SINAMICS, Micromaster, and SIMOVERT

Siemens drives — SINAMICS G120, S120, G150, and S150, along with legacy Micromaster 420/430/440 and SIMOVERT Masterdrives — represent the largest installed base of industrial frequency converters in Europe. These drives range from compact 0.12 kW units to multi-megawatt systems controlling everything from building ventilation to steel rolling mills. The breadth of the Siemens drive portfolio means repair engineers must understand multiple hardware platforms and generations of drive technology.

Common Siemens drive failures vary by series. Micromaster drives frequently suffer from electrolytic capacitor aging, IGBT failures, and control board SMPS faults. SINAMICS G120 power modules develop IGBT and current sensor failures, while CU control units can experience firmware corruption or communication module faults. SINAMICS S120 line modules and motor modules face high-power IGBT failures, DC link issues, and Active Interface Module (AIM) problems. Legacy SIMOVERT Masterdrives are prone to capacitor aging, CUR board failures, and CBP communication board issues.

At EFIXLAB, we repair all Siemens drive generations — from SIMOVERT through current SINAMICS platforms. Our capabilities include power module rebuild with original-specification IGBT modules, DC link capacitor bank replacement, control unit diagnostics and repair (including firmware recovery), and comprehensive testing with Siemens STARTER/TIA Portal diagnostics. We maintain extensive component stocks for rapid turnaround on common Siemens drive models.

Siemens drive repair delivers substantial savings across all product lines, with typical cost reductions of 40–70% versus new drive purchase. This is particularly significant for SINAMICS S120 booksize and chassis units, and for legacy Micromaster and SIMOVERT drives that Siemens no longer manufactures. All Siemens drive repairs at EFIXLAB include full-power load testing and carry our standard 12-month warranty on all work performed.